China Outdoor High Voltage Vacuum Circuit Breaker
≥2 Set
$8,200.00
Quantity:
If you have your own design, please contact us, there will have a professional customer service to communicate with you.
Don't have your files right now?No worries, Check out our art tips for more information.
If over 500pcs, mass production will start until pre-production sample has been approved.
Est. 7 days production
Quick Details | |
Place of Origin | CN;ZHE |
Brand Name | Jecsany |
Model Number | RVB-40.5 |
Type | Vacuum |
Poles Number | 3 |
RVB type outdoor vacuum circuit breaker covering 12kV up to 36kV range for transformer substation and switch station using.
The current rating: 630A,....2500A, short circuit breaking current rating: 25kA,...40kA.
Its perfect design for instead of traditional type like OHB,VBF,3AF,ZW7,ZW30,ZW39,ZW37...etc.
More light, compact, relieable, and friend-enviromental.
-------------------------------------------------------------------------------------------------------------------------------------------------------
1. Overview
JECSANY developed RVB-40.5 series of outdoor vacuum circuit breaker using modern processing technology and computer-aided design techniques, combined with the latest generation of spring bodies and the advantages of a permanent institution. Its pursuit of high reliability, easy to maintain design concepts to create a generation of superior product, is the most reliable electric power system the best option.
RVB-40.5series of switches of the main use Ansoft software and solidwork designed with the overall nice, safe and reliable.
RVB-40.5Series switches have a variety of styles to choose from:
RVB-40.5Nordinary outdoor vacuum circuit breakers, spring actuator come standard with mechanical life of 20,000 times.
JECSANY all series switches meet the following criteria:
ANSI/IEEE C37.60/IEC 62271-100( GB1984-2003 China standard)
GBT11022-1999 China Standard
IEC 60255-11
IEC 60255-21-1 Class I
IEC 60255-21-2 Class I
IEC 60255-21-3 Class I
IEC 60255-22-1 Class III
IEC 60255-22-2 Class IV
IEC 60255-22-3 Class III
IEC 60255-22-4 Class IV
2.Use of the environment
Ambient temperature: -40 ℃~ +85 ℃, the daily average temperature:25 ℃;
Altitude: ≤3000m(in excess of the value of technical discussions with the Division I);
Wind speed:35m/ s;
Earthquake intensity: not more than 8 degrees;
Degree of ambient air contamination level not greater than: Ⅲ level;
Daily average ambient air relative humidity ≤ 95%, on average ≤ 90%;
Saturated vapor pressure of daily mean values ≤ 2.2 × 10-3Mpa, on average ≤ 1.8 × 10-3Mpa;
More than the use of environmental conditions, please consult with the manufacturer.
3.RVB-40.5 Spring type VCB main characteristics
Reliable manual opening device Reliable and labor-saving manual closing Visible sub-closing indicator IP64 protection class plug connector Description: JECSANY offer a unique design of the manual switch on technology to meet the state of conventional and unconventional features of the Closing. Its speed to meet IEC62271-100 and similar GB1984-2003 standard requirements. The emergence of the technology to make up for the permanent institutions and agencies in their respective spring shortcomings, is a new generation of high-performance power switching distinguishing features. Primary busbar terminal (direct overlap with the interrupter to reduce unnecessary power losses) Vacuum interrupter (APG process using solid-solid insulating sealing technology, plus silicone rubber molding compound technology to improve the overall switch weather performance) Extensible outlet pipe (plus modular design, which will help insulation margin of certainty and product interchangeability requirements) RVB series vacuum switch rejection of the traditional switch design concepts, will absorb some of the advanced design concepts, simplifying the overall transmission mode switch, greatly reducing the transmission power loss of this switch makes switching better overall performance and longer life. Makes the whole body switches provide a higher life expectancy, more stable mechanical properties. RVB-40.5N provide up to 25,000 times the mechanical operation of life, institutions 20,000 times the number of maintenance-free operation. RVB-40.5Mto provide up to 100,000 times the mechanical operation of life. |
4.Technical data
No. | Item | unit | Data |
| ||||||||
1 | Rated voltage | kV | 12/24/36/40.5 |
| ||||||||
2 | Power frequency | Wet | 42/65/70/95 |
| ||||||||
Dry | 45/70/80/110 |
| ||||||||||
Lingthning impluse withstand voltage(peak value) | 75/95/125/150/170/185/200 |
| ||||||||||
3 | Rated current | A | 630/1250A/1600/2000/2500A |
| ||||||||
4 | Rated short circuit breaking current | kA | 25/31.5/40 |
| ||||||||
5 | Rated capacitor bank breaking current | A | 600/800 |
| ||||||||
6 | Rated short circuit breaking times | times | 30 |
| ||||||||
7 | Rated making current | kA | 63/80/100 |
| ||||||||
8 | Rated short circuit peak withsatnd current |
| ||||||||||
9 | Rated shortcircuit withstand current | 25/31.5/40 |
| |||||||||
10 | Rated short time duration time | S | 3/4 |
| ||||||||
11 | Complete breaking time | ms | ≤100 |
| ||||||||
Opening time | Highest operate voltage | 15~50 |
| |||||||||
Rated operate voltage | 15~50 |
| ||||||||||
Lowest operate voltage | 30~60 |
| ||||||||||
Closing time | 25~50 |
| ||||||||||
12 | Contact closing bounce time | ms | ≤3 |
| ||||||||
Out of simultaneity of contact switching | ms | ≤2 |
| |||||||||
Contact overitravel on Opening | mm | ≤2 |
| |||||||||
13 | Mechanical life | 20000(Normal) |
| |||||||||
14 | Electrical life(Rated onload switching) | 10000(Noraml) |
|
| ||||||||
15 | Rated operate sequence | O-0.3-CO-180S-CO |
| |||||||||
16 | Weight | ≤250kg |
|
Q: Can we get a sample for reference?
A: Yes, as long as the goods are conventional type, and you will be charged sample cost plus related shipping cost. Once you place an order to us, we can return or deduct the sample cost to you.
Q: How to solve the quality problems after sales?
A: Take photos of the quality problems and send to us for our checking and confirming, we will make a satisfied solution for you within 3 days.
Q: What is the lead time?
A: The lead time depends on the quantities ordered, generally within 25-35days upon the receipt of advance payment.
Q: What is your terms of payment ?
A: We accept West Union, T/T, irrevocable L/C at sight. Prefer T/T 30% deposit before production, the balance against copy of B/L.
Q: Can you print our brand on the product?
A: Yes, of course, we also do OEM to print client’s brand on the product.



Business Type | Trading Company | Country / Region | Zhejiang, China |
Main Products | Cable Accessories,Surge Arresters,Fuse Cutouts,Isolates Switches,Reclosers | Total Employees | 5 - 10 People |
Total Annual Revenue | confidential | Year Established | 2017 |
Certifications | ISO9001 | Product Certifications | |
Patents | Trademarks | ||
Main Markets | Africa 46% South America 30% Domestic Market 10% |
JECSANY has been thrived on supplying the products according to the international standard such as 61952, IEC 61109, IEC 60099-4, IEC 60282-2, etc. With scientific administration, professional engineers, highly trained technicians and skilled workers, JECSANY is capable to produce more than 2 million units of the main electrics in best quality annually, almost all of its products have been made for overseas markets and well sold to USA, South Africa, Vietnam, Korea, South America, South Asia etc. over 50 countries worldwide. Some of its products have already been granted IEC certificates and have won high reputation around world market.
In order to meet new challenge and satisfy increased customers' demand on our products and quality, JECSANY will consistently keep on updating and developing more products for new and old clients. We are looking forward to your mutual cooperation and support as usual .
No need register, just fill in contact info below, we will reply you within 24 hours!
Enter the code in the box below: